Announcements and Events
Upcoming NMR/MRI Events
Past Events
- August 21-25, 2011, Frankfurt am Main, Germany, Euromar 2011 Conference
- June 27-29, 2012, Dublin, Ireland, Euromar 2012 Conference
- September 9-13, 2012, Surrey, UK, Magnetic Resonance in Porous Media, MRPM 11
- May 5-11, 2012, Melbourne, Australia, ISMRM 20th Annual Meeting and Exhibition
- April 14-19, 2013, Asilomar, CA, USA, ENC 2013 Conference
- April 20-26, 2013, Salt Lake City, Utah, USA, ISMRM 21st Annual Meeting and Exhibition
- June 28-29, 2013, Hersonissos, Crete, Greece, Euromar 2013 Conference
- October 3-5, 2013, Toulouse, France, ESMRMB 2013 Conference
- October 14-18, 2013, Podstrana, Croatia, ISMRM Workshop on Diffusion as a Probe of Neural Tissue Microstructure
- October 15-17, 2013, Ettlingen, Germany, Preclinical User's Meeting
- November 6-8, 2013, Ettlingen, Germany, Basic Imaging Course
- November 11-15, 2013, Ettlingen, Germany, Advanced Imaging Course
- November 18-22, 2013, Ettlingen, Germany, Paravision Programming Course
Future Events
- March 23-28, 2014, Boston, MA, USA, ENC 2014 Conference
- May 10-16, 2014, Milan, Italy, ISMRM 22nd Annual Meeting and Exhibition
MRI News
Upgrade of the 7T Pharmascan
MIC is happy to inform you that a major upgrade of our MRI equipment was performed in Dec 2012. This upgrade included the following:
1. New animal beds for mice and rats;
2. New RF coils: this will include new volume coils (similar design as what we have now, but improved hardware properties), surface coils for mouse and rat brain imaging, and surface coils for imaging tumors close to the skin, for instance implantations on the extremities. All these coils are going to improve SNR (signal-to-noise ratio) of the images and/or imaging time;
3. New shim system: the new shim system will improve magnetic field homogeneity which will especially benefit spectroscopic, diffusion and perfusion imaging;
4. New gradient coil: the new gradient coil and gradient amplifier will be able to deliver more than 2 times (760 versus 300 mT/m) the gradient strength we have now. This will improve especially measurements of diffusion, but also in some cases resolution of the images;
5. New computer controlling the imager: more storage space, better RAM.
You can read more about the upgrade here